By Eric Ford, Vice President, Graphite Metallizing Corporation
Pump Engineer, November 2014
The Area Maintenance Engineer started looking for a longer-lasting option to reduce costs. While the pump was originally supplied with stainless steel bushings and impeller wear rings, these were subject to galling on start-up, and during upset conditions. An upgrade to PEEK material resolved the galling issue, but over time the resin binder started to break down allowing critical clearances to increase and pump performance to drop off. The repair shop suggested switching to a higher,more expensive grade of PEEK.
This idea was rejected as there was no guarantee that the new PEEK material would hold up any better as it had not been tested or used in this service before. After more research, the decision was made to replace the bushings and wear rings with nickel-filled GRAPHALLOY® graphite/metal alloy components, which allow the graphite layers to slide against each other resulting in excellent dry lubrication, is stable chemically, unaffected by ordinary solvents, and can withstand high temperatures without deformation or burning.
The pump internals are 300 series stainless steel. The supplier provided wear rings that were finish machined and installed into the pump’s 300 series stainless steel housings. The new material was installed into the eye and hub-side stationary rings, as well as the throat, throttle and center bushings. The first GRAPHALLOY-fitted spare rotor was installed into the pump. The damaged rotor with the PEEK bushings was sent to the shop and fitted with new graphite-based components.
The pump has been through several start/stop cycles and over a year in continuous service without any indication of increasing wear ring clearance or degradation. It has exceeded the runtimes of the previous bushings
Click here to learn more about GRAPHALLOY.
No comments:
Post a Comment